Model |
SUN-3.6K-SG01/03LP1-EU |
SUN-5K-SG01/03LP1-EU |
SUN-8K-SG01LP1-US/EU |
Battery Input Data |
Battery Type |
Lead-acid or Lithium-ion |
Battery Voltage Range (V) |
40~60V |
Max. Charging Current (A) |
90A |
120A |
190A |
Max. Discharging Current (A) |
90A |
120A |
190A |
Charging Curve |
3 Stages / Equalization |
External Temperature Sensor |
YES |
Charging Strategy for Li-Ion Battery |
Self-adaption to BMS |
PV String Input Data |
Max. DC Input Power (W) |
4680W |
6500W |
10400W |
PV Input Voltage (V) |
370V (100V~500V) |
MPPT Range (V) |
125~425V |
Full Load DC Voltage Range |
240~425V |
Start-up Voltage (V) |
150V |
PV Input Current (A) |
13A+13A |
13A+13A |
22A+22A |
No.of MPPT Trackers |
2 |
No.of Strings Per MPPT Tracker |
1+1 |
1+1 |
2+2 |
AC Output Data |
Rated AC Output and UPS Power (W) |
3600W |
5000W |
8000W |
Max. AC Output Power (W) |
3960W |
5500W |
8800W |
Peak Power (off grid) |
2 times of rated power, 10 S |
AC Output Rated Current (A) |
15.7A |
21.7A |
33.4A / 35A |
Max. AC Current (A |
18A |
25A |
36.7A / 38.5A |
Max. Continuous AC Passthrough (A) |
35A |
35A |
50A |
Power Factor |
0.8 leading to 0.8 lagging |
Output Frequency and Voltage |
50 / 60Hz; 120 / 240Vac (split phase), 208Vac (2 / 3 phase), 230Vac (1phase) |
Grid Type |
Split phase; 2 / 3 phase; Single Phase |
Current Harmonic Distortion |
THD<3%(Linear load<1.5%) |
Efficiency |
Max. Efficiency |
97.60% |
97.60% |
97.60% |
Euro Efficiency |
96.50% |
96.50% |
97.00% |
MPPT Efficiency |
99.90% |
96.50% |
99.90% |
Protection |
PV Input Lightning Protection |
Integrated |
Anti-islanding Protection |
Integrated |
PV String Input Reverse Polarity Protection |
Integrated |
Insulation Resistor Detection |
Integrated |
Residual Current Monitoring Unit |
Integrated |
Output Over Current Protection |
Integrated |
Output Shorted Protection |
Integrated |
Output Over Voltage Protection |
Integrated |
Surge protection |
DC Type II / AC Type II |
Certifications and Standards |
Grid Connection Standard |
EN50549-1, CEI 0-21, IEC61727, IEC62116, IEC60068, IEC61683, ABNT NBR 16149, ABNT NBR 16150, AS4777.2, VDE 4105, XP C15-712-3, |
RD1699, UNE 206006 IN, UNE 206007-1 IN |
Safety EMC / Standard |
IEC62040-1,IEC62109-1/-2,IEC61000-6-1,IEC61000-6-3,IEC61000-3-11, IEC61000-3-12, IEC61000-4-16,IEC61000-4-18,IEC61000-4-29 |
General Data |
Operating Temperature Range (ºC) |
-25~60ºC, >45ºC Derating |
Cooling |
Natural cooling |
Smart cooling |
Noise (dB) |
<30dB |
Communication with BMS |
RS485; CAN |
Weight (kg) |
20.5 |
32 |
Size (mm) |
330W×580H×232D |
420W×670H×233D |
Protection Degree |
IP65 |
Installation Style |
Wall-mounted |
Warranty |
5 years |
|
|
|
|