Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 10 Years |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The following illustration shows basic application of this inverter. It also includes following devices to have a Complete running system.
- Generator or Utility
- PV modules
Consult with your system integrator for other possible system architectures depending on your requirements.
This inverter can power all kinds of appliances in home or office environment, including motor type appliances such as
refrigerator and air conditioner.
Model |
SUN-3.6K
-SG03LP1-EU
|
SUN-5K
-SG03LP1-EU
|
SUN-6K
-SG03LP1-EU
|
SUN-8K
-SG01LP1-EU
|
AC Output | Single Phase | Single Phase | Single Phase | Single Phase/Three Phase |
DC Input(PV Side) | ||||
Max DC input Power | 4680W | 6500W | 7800W | 10400W |
Max DC input Voltage | 500V | |||
Start-up Input Voltage | 150VDC | |||
Rated Input Voltage | 370V(100V~500V) | |||
MPPT Voltage Range | 125V-425V | |||
Number of MPPT | 2/1+1 | |||
Max. Operating PV Input Current (A)
|
13A+13A | 13A+13A | 13A+13A | 13A+13A |
Battery Parameters | ||||
Battery Type | Lithium-ion,Lead-acid | |||
Nominal battery Voltage | 48VDC | |||
Battery voltage range | 40-60VDC | |||
Maximum Charging Current | 90A | 120A | 135A | 190A |
Maximum Discharging Current | 90A | 120A | 135A | 190A |
Charging curve | 3Stages/Equalization | |||
Charging Strategy for Li-Ion Battery | Self-adaption to BMS | |||
AC Output(Grid Side) | ||||
Rated AC Output and UPS Power (W) | 3600W | 5000W | 6000W | 8000W |
Max AC Output Power (W) | 3960W | 5500W | 6600W | 8800W |
Peak Power(off grid) | 2 times of rated power, 10 S | |||
Output Voltage |
220/230/240Vac
(single phase)
|
220/230/240Vac
(single phase)
|
120/240Vac; 110/220Vac(split phase), 208Vac(2/3 phase), 220/230/240Vac(single phase) | |
Grid Type | Split phase ,2/3 phase ,Single Phase | |||
Norminal Frequency | 50/60HZ | |||
Grid Frequency Range | 47-55/54-66HZ (According to local standard) | |||
AC Output Rated Current(A) | 16.4/15.7A | 22.7/21.7A | 27.3/26.1A | 36.4A/34.8A |
Max.AC Current(A) | 18/17.2A | 25/23.9A | 30/28.7A | 40/38.3A |
THDI | THD<3%(Linear load<1.5%) | |||
Power Factor | 1 default(+/-0.8 adjustable) | |||
EFFICIENCY | ||||
Max.Efficiency | 97.6% | |||
MPPT Efficiency | 99.9% | |||
PROTECTION | ||||
PV Input Lightning Protection | Integrated | |||
Anti-islanding Protection | Integrated | |||
PV String Input Reverse Polarity Protection | Integrated | |||
Output Over Current Protection | Integrated | |||
Output Shorted Protection | Integrated | |||
Output Over Voltage Protection | Integrated | |||
General Data | ||||
Operating Temperature Range (ºC) | -25~60ºC, >45ºC Derating | |||
Cooling | fan | |||
Communication with BMS | RS485, CAN | |||
Weight | 20.5KG | 20.5KG | 32KG | 32KG |
size | 580×330×208 mm | 580×330×208 mm | 670×420×233mm | 670×420×233mm |
Display | LCD Display | |||
Protection Degree | IP65 | |||
Grid Regulation | EU Standard; US Standard |
Model | SUN-10K-SG04LP3-EU | SUN-12K-SG04LP3-EU | |
Battery | |||
Battery Type | lithium ion/lead acid battery | ||
Battery Voltage Range | 40-60V | ||
MAX Charging Current | 210A | 240A | |
MAX Discharger Current | 210A | 240A | |
Charging Curve | 3Stages/Equalization | ||
External Temperature Sensor | YES | ||
Charging strategy for Lithium battery | Self adaptation to BMS | ||
PV Input Data | |||
MAX PV Input Power | 13000W | 15600W | |
MAX PV Input Voltage | 800VDC | ||
MPPT Voltage Range | 200-650VDC | ||
PV Input Current | 26A+13A | 26A+13A | |
NO. Of MPPT Trackers | 2 | 2 | |
No. of PV Strings per MPPT | 2+1 | 2+1 | |
AC Output Data | |||
Rated AC Output Power and UPS power | 10000W | 12000W | |
MAX AC Output Power | 11000W | 13200W | |
Peak Power of OFF GRID | 2TIMES of Rated Power, 10S. | ||
AC Output Rated Current | 15A | 18A | |
Max. Continuous AC Passthrough (A) | 50A | 50A | |
Output Frequency and Voltage | 50/60Hz; 230/400Vac (Three phase) | ||
Current Harmonic Distortion | THD<3% (Linear load<1.5%) | THD<3% (Linear load<1.5%) | |
Efficiency | |||
MAX Efficiency | 97.60% | 97.60% | |
MPPT Efficiency | 99.90% | 99.90% | |
Protection | |||
PV Input Lightning Protection | Integrated | Integrated | |
Anti-islanding Protection | Integrated | Integrated | |
PV String Input Reverse Polarity Protection | Integrated | Integrated | |
Output Over Current Protection | Integrated | Integrated | |
Output Over Voltage Protection | Integrated | Integrated | |
Surge protection | DC Type II / AC Type II | DC Type II / AC Type II | |
Certiffcations and Standards | |||
Grid Regulation | IEC61727, IEC62116, IEC60068, IEC61683, NRS 097-2-1 | IEC61727, IEC62116, IEC60068, IEC61683, NRS 097-2-1 | |
Safety EMC/Standard | IEC62109-1/-2, IEC61000-6-1, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 | IEC62109-1/-2, IEC61000-6-1, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 |